Prosthodontic treatment of a patient with a burdened allergic history by 3D milled complete removable prosthesis was performed. Materials and methods. The clinical case of treating a patient with a full adentia on the lower jaw and allergy to the used earlier acrylic prosthesis. Computer simulation of the prosthesis was carried out in the Exocad program. Removable prosthesis has been fabricated on a 3D milling apparatus with 5 micron precision from non-monomer containing polymethylmethacrylic discs. Results. The manufacture of the prosthesis was carried out according to an individual method by milling individual sections of the base and teeth, which made it possible to individualize the height of the base and choose a shade for the teeth for better aesthetics. The algorithm for designing the dentition is similar to that used in traditional methods of prosthetics. By combining the milled base and teeth, the final complete removable denture was obtained. Conclusion. The technique eliminates the release of residual monomer from the prosthetic bed to the mucous membrane, and also prevents injection molding errors such as shrinkage, gas porosity, and compression porosity. The use of a milled full denture allows you to restore the integrity of the dentition and eliminate all manifestations of allergic reactions, as well as their complications. Digital technologies reduces visits to the clinic. The use of milled prostheses is very promising in patients with a burdened allergic history.
Key words:
CAD/CAM, allergy, dentistry, denturesFor Citation
References
- Abolmasov N.G., Abolmasov N.N., Adaeva I.A., Kovaleva I.A., Geletin P.N., Solov’ev A.A., Serdyukov M.S. Comparison of different methods to design full removable prostheses; criteria and correction of adaptation processes. — Russian dental journal. — 2010; 4: 24—8 (In Russ.).
- Astrvacatryan L.E., Gazhva S.I. Modern aspects of the use of 3D-technology in the manufacture of removable dentures. — Modern problems of science and education. — 2017; 5: 194—9 (In Russ.).
- Vagner V.D., Smirnova L.E., Saleev R.A., Bochkovskij I.S., Vashurin I.V. Technologies for orthopedic treatment of dental patients. — Clinical Dentistry (Russia). — 2010; 1 (53): 12—5 (In Russ.).
- Verhulevskij R.A., Sabirova D.K., Saleev R.A. Modern methods of scanning in dentistry. — Proceedings of “Actual issues of dentistry”. — Kazan, 2019. — P. 59—64 (In Russ.).
- Gujter O.S., Mitin N.E., Olejnikov A.A., Manichkina A.R., Serdceva M.S. Chewing efficacy in patients with extensive acquired maxillary defects after orthopedic rehabilitation. — Dentistry. — 2019; 4: 80—3 (In Russ.).
- Konnov V.V., Arutyunyan M.R. Comparative analysis of clinical and functional adaptation to partial dentures based on nylon and acrylic plastic. — Modern problems of science and education. — 2015; 3: 8 (In Russ.).
- Konnov V.V., Razakov D.H., Klenkova M.I., Anisimova Y.U. The value of the neutral zone during the relocation of complete removable laminar dentures. — Modern problems of science and education. — 2014; 5: 532 (In Russ.).
- Korotkih N.G., Mitin N.E., Ponomaryov E.O., Mishin D.N. A comparative analysis of the retention configuration basis points or direct dentyre maxiiofacial prosthesis on the postoperative rehabilitation. — Modern problems of science and education. — 2015; 4: 409 (In Russ.).
- Marenkova M.V. Features of orthopedic treatment of patients with intolerance phenomena of dentures against the background of microbial imbalance of the oral cavity: master’s thesis. — Yekaterinburg, 2007. — 143 p. (In Russ.).
- Mitin N.E., Vasil’eva T.A., Strelkov N.N., Vasil’ev E.V., Kaplan M.B. A new approach to assessing masticatory effectiveness in the post-rehabilitation period in dental patients using computer technology. — Biomedical Electronics. — 2016; 6: 45—51 (In Russ.).
- Rabinovich O.F., Rabinovich I.M., Abramova E.S. Manifestations of dysbiosis and candidiasis in various diseases of the oral mucosa. — Clinical Dentistry (Russia). — 2011; 3 (59): 48—51 (In Russ.).
- Rabinovich O.F., Rabinovich I.M., Ostrovskij A.D., Denisova M.A. Negative effect of orthopedic materials on the oral mucosa. — Maestro of dentistry. — 2011; 41: 10 (In Russ.).
- Ryahovskij A.N., Polyakova M.V. Computer design of dentitions for complete dentures. — Dentistry. — 2011; 2: 65—70 (In Russ.).
- Salivonchik M.S. Experimental and clinical substantiation of the effectiveness of the final processing of removable constructions of dentures from thermoplastic polymers: master’s thesis. — Voronezh, 2015. — 135 p. (In Russ.).
- Utyuzh A.S., Yumashev A.V., Lushkov R.M. A clinical example of orthopedic treatment of a patient after resection of the lower jaw for sarcoma using dental implants. — Clinical Dentistry (Russia). — 2016; 4 (80): 56—8 (In Russ.).
- Thalji G., Jia-mahasap W. CAD/CAM removable dental prostheses: a review of digital impression techniques for edentulous arches and advancements on design and manufacturing systems. — Current Oral Health Reports. — 2017; 4: 151—7. DOI: 10.1007/s40496-017-0137-z
- Han W., Li Y., Zhang Y., Lv Y., Zhang Y., Hu P., Liu H., Ma Z., Shen Y. Design and fabrication of complete dentures using CAD/CAM technology. — Medicine (Baltimore). — 2017; 96 (1): e5435. PMID: 28072686