DOI:
10.37988/1811-153X_2020_2_61The early functional loading protocol’s efficiency for various dental implants
Downloads
Abstract
The objective was to find out the early functional load effectiveness upon the dental implants installing of various systems, shapes, sizes. Materials and methods. The single center clinical, x-ray (CT, orthopantomography ) and laboratory study of 60 people for 2 years was conducted. Conclusions. Various root-type and cylindrical system implants are equally suitable for early functional load protocols. The implanted structures overall survival is 97.8%. Conical dental implants are in favour for implantation in the maxilla, cylindrical one is preferably for implantation in the mandibula. Short implants (less than 8 mm) do not ensure effective dental implants survival with early functional load.
Key words:
dental implantation, implantation, osseointegration, coating, functional loadFor Citation
References
- Ashuev Zh.A. To the question of substantiation of optimal terms of functional loads during dental implantation. — Medical Alphabet. — 2012; 7: 30—2 (In Russ.).
- Gus’kov A.V., Mitin N.E., Zimankov D.A., Mirnigmatova D.B., Grishin M.I. Dental implants: state of the question today (literature review). — Clinical Dentistry (Russia). — 2017; 2 (82): 32—4 (In Russ.).
- Nikitin A.A., Polupan P.V., Sipkin A.M., Nikitin D.A. Long-term results of the use of a one-stage surgical protocol of an operation and one-stage dental implants. — Medical Alphabet. — 2016; 29 (292): 42—9 (In Russ.).
- Ostashko A.A., Sizova S.V., Labis V.V. An experimental model of dental implantation. — Orenburg Scientific Center of the Russian Academy of Sciences Ural branch bulletin. — 2016; 2: 14 (In Russ.).
- Smirnova L.E., Filimonova L.B. Legislative and regulatory legal support of dental implantation. — Dentistry. — 2016; 6: 129—30 (In Russ.).
- Ushakov R.V. The use of BoneTrust plus dental implants with direct dental implantation and immediate loading. — Dentistry for All. — 2013; 2: 18—21 (In Russ.).
- Fokina A.A., Evstafieva O.L. Biochemical studies in assessing the integration of dental implants. — Proceedings of the conference “In the world of science and innovation”, Kazan, 2017. — Ufa: Aeterna, 2017. — Pp. 191—195 (In Russ.).
- Alghamdi H.S. Methods to improve osseointegration of dental implants in low quality (type-IV) bone: An overview. — J Funct Biomater. — 2018; 9 (1): 7. PMID: 29342830
- Aykas Yu. Features of individual oral hygiene in patients with dental implants. — Practitioner Dentist. — 2014; 2: 32—3 (In Russ.).
- Cannizzaro G., Gastaldi G., Gherlone E., Vinci R., Loi I., Trullenque-Eriksson A., Esposito M. Two or three machined vs roughened surface dental implants loaded immediately supporting total fixed prostheses: 1-year results from a randomised controlled trial. — Eur J Oral Implantol. — 2017; 10 (3): 279—91. PMID: 28944356
- Degidi M., Daprile G., Piattelli A. Determination of primary stability: A comparison of the surgeon’s perception and objective measurements. — Int J Oral Maxillofac Implants. — 2010; 25 (3): 558—61. PMID: 20556255
- Degidi M., Daprile G., Piattelli A. Influence of underpreparation on primary stability of implants inserted in poor quality bone sites: An in vitro study. — J Oral Maxillofac Surg. — 2015; 73 (6): 1084—8. PMID: 25861691
- Gottlow J., Barkarmo S., Sennerby L. An Experimental Comparison of Two Different Clinically Used Implant Designs and Surfaces. — Clin Implant Dent Relat Res. — 2012; 14 Suppl 1: e204—12. PMID: 22487460
- Guida L., Iezzi G., Annunziata M., Salierno A., Iuorio G., Costigliola G., Piattelli A. Immediate placement and loading of dental implants: a human histologic case report. — J Periodontol. — 2008; 79 (3): 575—81. PMID: 18315443
- Guljé F., Abrahamsson I., Chen S., Stanford C., Zadeh H., Palmer R. Implants of 6 mm vs. 11 mm lengths in the posterior maxilla and mandible: a 1-year multicenter randomized controlled trial. — Clin Oral Implants Res. — 2013; 24 (12): 1325—31. PMID: 22938573
- Huang H.-L., Chang Y.-Y., Lin D.-J., Li Y.-F., Chen K.-T., Hsu J.-T. Initial stability and bone strain evaluation of the immediately loaded dental implant: an in vitro model study. — Clin Oral Implants Res. — 2011; 22 (7): 691—8. PMID: 21054551
- Javed F., Romanos G.E. The role of primary stability for successful immediate loading of dental implants. a literature review. — J Dent. — 2010; 38 (8): 612—20. PMID: 20546821
- Merli M., Moscatelli M., Mariotti G., Piemontese M., Nieri M. Immediate versus early non-occlusal loading of dental implants placed flapless in partially edentulous patients: a 3-year randomized clinical trial. — J Clin Periodontol. — 2012; 39 (2): 196—202. PMID: 22118014
- Mura P. Immediate loading of tapered implants placed in postextraction sockets: retrospective analysis of the 5-year clinical outcome. — Clin Implant Dent Relat Res. — 2012; 14 (4): 565—74. PMID: 20662861
- Pozzi A., Mura P. Immediate loading of conical connection implants: up-to-2-year retrospective clinical and radiologic study. — Int J Oral Maxillofac Implants. — 2016; 31 (1): 142—52. PMID: 26800171
- Romanos G.E., Toh C.G., Siar C.H., Swaminathan D. Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading: an experimental study with Macaca Fascicularis. — Int J Oral Maxillofac Implants. — 2002; 17 (1): 44—51. PMID: 11858574
- Simunek A., Kopecka D., Brazda T., Strnad I., Capek L., Slezak R. Development of implant stability during early healing of immediately loaded implants. — Int J Oral Maxillofac Implants. — 2012; 27 (3): 619—27. PMID: 22616056
- Tatum C.L., Saltz A.E., Prihoda T.J., DeGroot B.S., Mealey B.L., Mills M.P., Huynh-Ba G. Management of thick and thin periodontal phenotypes for immediate dental implants in the esthetic zone: a controlled clinical trial. — Int J Periodontics Restorative Dent. — 2020; 40 (1): 51—9. PMID: 31815973
- Torsiglieri T., Raith S., Rau A., Deppe H., Hölzle F., Steiner T. Stability of edentulous, atrophic mandibles after insertion of different dental implants. a biomechanical study. — J Craniomaxillofac Surg. — 2015; 43 (5): 616—23. PMID: 25865491