Biomechanical provision of appliance of an osseointegrated post for dental replantation
Downloads
Abstract
The article provides with data of calculation of replanted tooth and fixing osseointegrated post strain-stress state. The research states the optimal size of an osseointegrated post and its location towards replanted tooth, also the ability of an osseointegrated post to fix a replanted tooth and function durably at a constant maximum mastication load.Key words:
replantation, intramedullary pinFor Citation
[1]
Ivashenko A.V., Monakov V.A., Monakov D.V., Volova L.T. Biomechanical provision of appliance of an osseointegrated post for dental replantation. Clinical Dentistry (Russia). 2015; 1 (73): 48—50
References
- Антоневич В.М. О реплантации и трансплантации зубов: дис. … д.м.н. - М., 1885. - 95 с.
- Богатов А.И. Модифицированный способ реплантации зубов. - Сб. статей I международного конгресса по проблемам зубной трансплантологии. - Уфа, 1994. - С. 40-42.
- Богатов А.И. Реплантация зубов. - Сб. статей V съезда стоматологической ассоциации России. - М., 1999. - С. 226-227.
- Akiyama Y., Fukuda H., Hashimoto K. A clinical and radiographic study of 25 autotransplanted third molars. - J Oral Rehabil. - 1998: 25 (8): 640-4.
- Akkocaoglu M. Kasaboglu O. Success rate of autotransplanted teeth without stabilization by splints: a long-term clinical and radiological follow-up. - Br J Oral Maxillofac Surg. - 2005; 43 (1): 31-5.
- Andersen J.O. Atlas of replantation and transplantion of teeth. - 1992. - P. 207.
- Andreasen J.O. Replantation of 400 avulsed permanent incisors. Factors related to periodontal ligament healing. - Endodontics & Dental Traumatology. - 1995; 26 (11): 76-89.
Downloads